​Heat shrink medium voltage joints

CJ R10 series joints are single core, 15 kV to 35 kV, heat shrink repair joints for bare and jacketed concentric neutral cable. They are designed to repair faulted cables or joints by replacing the damaged area with a longer make-up connection. The CJ 10J series joints use the same joint components as the CJ R10 joints but are supplied with a wraparound jacketing sleeve to seal from cable jacket to cable jacket on jacketed concentric neutral cables.

Features and Benefits

  • Fast, consistent installation means lower installed costs
  • Installation environment: use of torch adds flexibility to cable preparation in any climate
  • Heat activated seal ensures maximum protection against moisture ingress
  • Custom tailored with options to your exacting needs
  • Lightweight construction requires no additional support
  • Wide cable ranges for reduced inventory requirements
  • Tough abrasion resistant outer covering protects against damage from improper backfill
  • Slim profile allows installation in confined areas

Standards

  • IEEE 404-2000

Test Reports

The CJ 10 series joints were design tested to IEEE 404-2000 at an independent laboratory as single core unjacketed joints. This represents the worst case condition as the joints submerged under water were not afforded the added protection of the CJ R10J series joints with jackets.

Test reports are available as follows:

  • CJ 1510 series: HVSO20080
  • CJ 2510 series: HVSO20081 and HVSO 20083
  • CJ 3510 series: HVSO20082

Ordering

  • Find the cables voltage class and conductor size(s) to be spliced. Select the kit order number that covers the conductor size range.
  • Confirm the dimensional data particularly when the conductor size is at the extremes of the range. The CJ R10 series joints are for bare concentric neutral cables. The CJ R10J series joints are for repairing jacketed concentric neutral cables. The determining factors for selection are that the minimum and maximum dimensions for the primary insulation and connector dimensions are met and that the jacket diameter maximum is not exceeded.
  • A cable preparation/cleaning kit can be included with the kit by adding the suffix to the end of the order number.

Product Properties

Bare Concentric Neutral

Order Number Conductor Size Range Insulation O.D. Range Jacket O.D. Maximum Connector Dimensions Nominal Kit Installed Length
Maximum O.D. Maximum Length
IN MM IN MM IN MM IN MM IN MM
15 KV (175 - 220 mils)
CJ R1511 #4 - 4/0 AWG 0.60 - 1.05 15 - 23 n/a n/a 0.90 23 10.0 254 24.0 610
CJ R1512 3/0 - 350 kcmil 0.80 - 1.25 20 - 32 n/a n/a 1.15 29 10.0 254 24.0 610
CJ R1513 400 - 750 kcmil 1.05 - 1.75 27 - 44 n/a n/a 1.60 41 12.0 300 26.0 660
CJ R1514 750 - 1000 kcmil 1.30 - 1.85 33 - 47 n/a n/a 1.85 47 12.0 300 26.0 660
25 - 28 kV (260 - 280 mils)
CJ R2511 #1 - 250 kcmil 0.80 - 1.20 20 - 30 n/a n/a 1.50 38 9.0 229 28.0 711
CJ R2512 4/0 - 500 kcmil 1.05 - 1.60 27 - 41 n/a n/a 1.95 50 11.0 279 30.0 762
CJ R2513 600 - 1000 kcmil 1.40 - 1.85 36 - 47 n/a n/a 2.40 61 16.0 400 32.0 813
35 kV (345 mils)
CJ R3511 1/0 - 250 kcmil 0.95 - 1.35 24 - 34 n/a n/a 1.00 25 10.0 254 30.0 762
CJ R3512 4/0 - 600 kcmil 1.30 - 1.75 33 - 44 n/a n/a 1.50 38 10.0 254 30.0 762
CJ R3513 600 - 1000 kcmil 1.55 - 2.15 39 - 55 n/a n/a 1.85 47 12.0 300 32.0 813

Jacketed Concentric Neutral

Order Number Conductor Size Range Insulation O.D. Range Jacket O.D. Maximum Connector Dimensions Nominal Kit Installed Length
Maximum O.D. Maximum Length
IN MM IN MM IN MM IN MM IN MM
15 kV (175 - 220 mils)
CJ R1511J #4 - 3/0 AWG 0.60 - 1.05 15 - 23 1.25 32 0.90 23 10.0 254 48.0 1220
CJ R1512J 3/0 - 400 kcmil 0.80 - 1.25 20 - 32 1.50 38 1.15 29 10.0 254 48.0 1220
CJ R1513J 400 - 750 kcmil 1.05 - 1.75 27 - 44 n/a n/a 1.60 41 12.0 300 26.0 660
CJ R1514J 750 - 1000 kcmil 1.30 - 1.85 33 - 47 n/a n/a 1.85 47 12.0 300 26.0 660
25 - 28 kV (260 - 280 mils)
CJ R2511J #1 - 250 kcmil 0.80 - 1.20 20 - 30 1.50 38 1.50 38 9.0 229 48.0 1220
CJ R2512J 4/0 - 500 kcmil 1.05 - 1.60 22 - 41 1.95 50 1.95 50 11.0 279 48.0 1220
CJ R2513J 600 - 1000 kcmil 1.40 - 1.85 36 - 47 2.40 61 2.40 61 16.0 400 52.0 1320
35 kV (345 mils)
CJ R3511J 1/0 - 250 kcmil 0.95 - 1.35 24 - 34 n/a n/a 1.00 25 10.0 254 30.0 762
CJ R3512J 4/0 - 600 kcmil 1.30 - 1.75 33 - 44 n/a n/a 1.50 38 10.0 254 30.0 762
CJ R3513J 600 - 1000 kcmil 1.55 - 2.15 39 - 55 n/a n/a 1.85 47 12.0 300 32.0 813

Market / Applications

  • Power Distribution
  • Power Distribution - MV
  • Utility

Documentation

Version: 01 2018/JAN/02
SEARCH PRODUCT CATALOG   
Need more information? Click here to contact us directly!
Our Success Stories

Our Success Stories

Discover Shawcor integrated services and advanced technologies being applied to the world’s largest projects in the most extreme and challenging environments. Lookup for any project by Geo-location, Capability, Technology and Service provided.

View more success stories
SEND US A MESSAGE