- Strand Bare (ASTM B8) Annealed Copper Conductors
- FR XLPE (XHHW-2 Rated) Insulated Conductors
- Polypropylene Fillers
- Polyester Separator Tape
- FR PVC Outer Protective Jacket
Part Number |
Number of Conductors |
Conductor Size (AWG/MCM) |
Nominal Diameter Overall Cable (in/mm) |
Cable Weight (lbs/1000ft)/ (kg/km) |
Ampacity (30°C ambient) |
Max. Pulling Tension (Pulling Eye) (lb/kg) |
Min. Bend Radius (Pull) (in/mm) |
2C010U140200300 |
2 |
14 |
0.372 / 9.45 |
72 / 108 |
25 |
66 / 30 |
3.3 / 85 |
2C010U140300300 |
3 |
14 |
0.392 / 9.96 |
90 / 134 |
25 |
99 / 45 |
3.5 / 90 |
2C010U140400300 |
4 |
14 |
0.426 / 10.83 |
111 / 166 |
20 |
132 / 60 |
3.8 / 97 |
2C010U140500300 |
5 |
14 |
0.465 / 11.81 |
130 / 194 |
20 |
165 / 75 |
4.2 / 106 |
2C010U140600300 |
6 |
14 |
0.505 / 12.83 |
153 / 228 |
20 |
197 / 90 |
4.5 / 115 |
2C010U140700300 |
7 |
14 |
0.505 / 12.83 |
167 / 249 |
17.5 |
230 / 104 |
4.5 / 115 |
2C010U140800300 |
8 |
14 |
0.575 / 14.6 |
207 / 308 |
17.5 |
263 / 119 |
5.2 / 131 |
2C010U141000300 |
10 |
14 |
0.668 / 16.97 |
256 / 381 |
12.5 |
329 / 149 |
6 / 153 |
2C010U141200300 |
12 |
14 |
0.688 / 17.48 |
291 / 433 |
12.5 |
395 / 179 |
6.2 / 157 |
2C010U141400300 |
14 |
14 |
0.722 / 18.35 |
331 / 493 |
12.5 |
461 / 209 |
6.5 / 165 |
2C010U141500300 |
15 |
14 |
0.741 / 18.83 |
351 / 522 |
12.5 |
494 / 224 |
6.7 / 169 |
2C010U142000300 |
20 |
14 |
0.841 / 21.36 |
453 / 674 |
12.5 |
658 / 298 |
7.6 / 192 |
2C010U142500300 |
25 |
14 |
0.974 / 24.74 |
590 / 878 |
11.25 |
823 / 373 |
8.8 / 223 |
2C010U143000300 |
30 |
14 |
1.028 / 26.12 |
680 / 1012 |
11.25 |
987 / 448 |
9.3 / 235 |
2C010U144000300 |
40 |
14 |
1.147 / 29.13 |
871 / 1296 |
10 |
1316 / 597 |
10.3 / 262 |
2C010U145000300 |
50 |
14 |
1.272 / 32.31 |
1067 / 1588 |
8.75 |
1645 / 746 |
11.4 / 291 |
2C010U120200300 |
2 |
12 |
0.408 / 10.36 |
95 / 141 |
30 |
104 / 47 |
3.7 / 93 |
2C010U120300300 |
3 |
12 |
0.431 / 10.94 |
122 / 182 |
30 |
157 / 71 |
3.9 / 98 |
2C010U120400300 |
4 |
12 |
0.47 / 11.94 |
150 / 224 |
24 |
209 / 95 |
4.2 / 107 |
*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(3)(a) for number of Conductors.
Part Number |
Number of Conductors |
Conductor Size (AWG/MCM) |
Nominal Diameter Overall Cable (in/mm) |
Cable Weight (lbs/1000ft)/ (kg/km) |
Ampacity (30°C ambient) |
Max. Pulling Tension (Pulling Eye) (lb/kg) |
Min. Bend Radius (Pull) (in/mm) |
2C010U120500300 |
5 |
12 |
0.514 / 13.05 |
183 / 272 |
24 |
261 / 118 |
4.6 / 117 |
2C010U120600300 |
6 |
12 |
0.589 / 14.96 |
233 / 347 |
24 |
313 / 142 |
5.3 / 135 |
2C010U120700300 |
7 |
12 |
0.589 / 14.96 |
255 / 380 |
21 |
365 / 166 |
5.3 / 135 |
2C010U120800300 |
8 |
12 |
0.634 / 16.11 |
283 / 421 |
21 |
418 / 189 |
5.7 / 145 |
2C010U121000300 |
10 |
12 |
0.74 / 18.8 |
351 / 523 |
15 |
522 / 237 |
6.7 / 169 |
2C010U121200300 |
12 |
12 |
0.763 / 19.37 |
405 / 602 |
15 |
626 / 284 |
6.9 / 174 |
2C010U121400300 |
14 |
12 |
0.802 / 20.37 |
460 / 685 |
15 |
731 / 331 |
7.2 / 183 |
2C010U121500300 |
15 |
12 |
0.823 / 20.91 |
488 / 727 |
15 |
783 / 355 |
7.4 / 188 |
2C010U122000300 |
20 |
12 |
0.976 / 24.8 |
672 / 1000 |
15 |
1044 / 474 |
8.8 / 223 |
2C010U122500300 |
25 |
12 |
1.082 / 27.48 |
821 / 1221 |
13.5 |
1305 / 592 |
9.7 / 247 |
2C010U123000300 |
30 |
12 |
1.144 / 29.06 |
953 / 1418 |
13.5 |
1566 / 710 |
10.3 / 261 |
2C010U124000300 |
40 |
12 |
1.278 / 32.47 |
1230 / 1831 |
12 |
2088 / 947 |
11.5 / 292 |
2C010U125000300 |
50 |
12 |
1.42 / 36.08 |
1515 / 2254 |
10.5 |
2610 / 1184 |
12.8 / 325 |
2C010U100200300 |
2 |
10 |
0.458 / 11.63 |
128 / 191 |
40 |
166 / 75 |
4.1 / 105 |
2C010U100300300 |
3 |
10 |
0.484 / 12.3 |
168 / 250 |
40 |
249 / 113 |
4.4 / 111 |
2C010U100400300 |
4 |
10 |
0.53 / 13.46 |
214 / 318 |
32 |
332 / 151 |
4.8 / 121 |
2C010U100500300 |
5 |
10 |
0.611 / 15.52 |
273 / 406 |
32 |
415 / 188 |
5.5 / 140 |
2C010U100600300 |
6 |
10 |
0.664 / 16.87 |
323 / 481 |
32 |
498 / 226 |
6 / 152 |
2C010U100700300 |
7 |
10 |
0.664 / 16.87 |
357 / 531 |
28 |
581 / 264 |
6 / 152 |
2C010U100800300 |
8 |
10 |
0.717 / 18.21 |
400 / 595 |
28 |
664 / 301 |
6.5 / 164 |
2C010U101000300 |
10 |
10 |
0.84 / 21.34 |
498 / 742 |
20 |
830 / 376 |
7.6 / 192 |
2C010U101200300 |
12 |
10 |
0.906 / 23.02 |
612 / 911 |
20 |
996 / 452 |
8.2 / 207 |
2C010U101400300 |
14 |
10 |
0.952 / 24.18 |
699 / 1040 |
20 |
1162 / 527 |
8.6 / 218 |
2C010U101500300 |
15 |
10 |
0.977 / 24.81 |
742 / 1104 |
20 |
1245 / 565 |
8.8 / 223 |
2C010U102000300 |
20 |
10 |
1.109 / 28.16 |
963 / 1434 |
20 |
1660 / 753 |
10 / 253 |
2C010U102500300 |
25 |
10 |
1.232 / 31.29 |
1179 / 1755 |
18 |
2075 / 941 |
11.1 / 282 |
2C010U103000300 |
30 |
10 |
1.304 / 33.12 |
1380 / 2053 |
18 |
2490 / 1129 |
11.7 / 298 |
2C010U104000300 |
40 |
10 |
1.461 / 37.1 |
1790 / 2664 |
16 |
3320 / 1506 |
13.1 / 334 |
2C010U105000300 |
50 |
10 |
1.626 / 41.31 |
2211 / 3291 |
14 |
4150 / 1882 |
14.6 / 372 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16. Values are corrected according to Table 310.15(C)(1) for number of Conductors.